c:\compare\MSL400BETA1FAILED\Modelica.Magnetic.FundamentalWave.Examples.BasicMachines.InductionMachines.IMC_Transformer.IMC_Transformer_report.html

Meta report:c:\compare\MSL400BETA1FAILED\
Base file:c:\Projekte\MAP-LIB_ReferenceResults\Modelica\Magnetic\FundamentalWave\Examples\BasicMachines\InductionMachines\IMC_Transformer\IMC_Transformer.csv
Compare file:c:\compare\Failed\Modelica\Magnetic\FundamentalWave\Examples\BasicMachines\InductionMachines\IMC_Transformer\IMC_Transformer.csv
Tolerance:0,002
Timestamp:13.02.2020 21:16:01 [UTC]
Compared results:The compare file contained 9 results.
9 results were tested.
1 result failed.
Success rate is 88,9%.
Average relative error:0,00
Failed tests:IMC_Transformer.aimc.stator.zeroInductor.i0

Value:IMC_Transformer.aimc.stator.zeroInductor.i0
Errors:1949 (relative error is 1,58630899807668E-06)

[Back to top]